Data Center Electrical Automation

End-to-end power chain management from utility to rack — UPS, precision cooling, and DCIM integration for Tier III/IV data centers with PUE below 1.4

Mission-Critical Infrastructure Automation

SENTRADO delivers comprehensive data center electrical automation solutions covering the entire power chain from medium-voltage utility intake to rack-level power distribution. Our integrated approach combines power management, precision cooling control, and environmental monitoring to ensure 99.999% uptime while optimizing PUE below 1.4.

With expertise spanning Schneider, Eaton, and Huawei platforms, we design and implement Tier III (concurrently maintainable) and Tier IV (fault-tolerant) data centers compliant with TIA-942, Uptime Institute, and GB 50174 standards.

99.999%
Uptime Availability
<1.4
PUE Target
25+
Years Experience
Tier III/IV
Design Compliant

Key Solutions

Comprehensive data center electrical automation from power intake to intelligent infrastructure management

Data center power distribution switchgear and UPS systems

Power Distribution

Complete medium and low voltage power distribution infrastructure including switchgear, automatic transfer switches, UPS systems, and rack-level power distribution units.

MV/LV switchgear (IEC 61439)
ATS dual power transfer
UPS 10-500kVA modular
Rack PDU with metering
Modular UPS system with redundant 2N architecture for data center

UPS Systems

Uninterruptible power supply systems from 10kVA to 500kVA with modular architecture, supporting N+1 and 2N redundant configurations for maximum availability.

10-500kVA capacity range
Modular hot-swap design
2N redundant architecture
Schneider / Eaton / Huawei
Precision cooling system CRAC CRAH in-row cooling data center

Precision Cooling

Advanced cooling control systems including CRAC/CRAH units, in-row precision cooling, and liquid cooling solutions with intelligent airflow management.

CRAC/CRAH unit control
In-row precision cooling
Liquid cooling control
Free cooling & economizer
Data center environmental monitoring temperature humidity sensors

Environmental Monitoring

Comprehensive environmental monitoring systems providing real-time data on temperature, humidity, smoke detection, and water leak prevention across all zones.

Temperature & humidity sensors
Smoke detection (VESDA)
Water leak detection
Multi-zone alarm management
DCIM data center infrastructure management monitoring dashboard

DCIM Integration

Seamless integration with Data Center Infrastructure Management platforms for real-time monitoring, capacity planning, energy reporting, and predictive analytics.

Real-time monitoring dashboard
Capacity planning tools
Energy & PUE reporting
SNMP / BACnet / Modbus TCP
PUE optimization energy efficiency data center cooling management

PUE Optimization

Systematic approach to achieving Power Usage Effectiveness below 1.4 through integrated cooling optimization, airflow management, and intelligent load balancing.

Hot/cold aisle containment
Economizer & free cooling
AI-driven cooling optimization
Energy benchmarking & reporting

Technical Expertise

Industry-leading technology partnerships and compliance with international data center standards

UPS Integration

Authorized integration partner for Schneider Galaxy/Symmetra, Eaton 93E/9PX, and Huawei UPS5000/UPS6000 series with full firmware and monitoring support.

Switchgear Standards

IEC 61439 compliant switchgear assemblies rated up to 4000A with comprehensive type testing, internal arc containment, and seismic qualification options.

Cooling Technologies

Free cooling with dry coolers, indirect evaporative economizers, raised-floor plenum, hot/cold aisle containment, and direct-to-chip liquid cooling for high-density racks.

Monitoring Protocols

Full protocol support including SNMP v3 for network management, BACnet/IP for building systems, and Modbus TCP for industrial devices, ensuring vendor-neutral integration.

Industry Standards

Designs comply with TIA-942 telecommunications infrastructure standard, Uptime Institute Tier classification (I-IV), and Chinese GB 50174 data center standard.

PUE Target

Systematic PUE optimization targeting below 1.4 through integrated mechanical, electrical, and control strategies. Proven results as low as 1.25 in optimal conditions.

Project Track Record

Proven experience delivering mission-critical data center electrical automation across industries

IBM R&D Center

Complete power and cooling automation system for IBM research facility, achieving Tier III compliance with 2N UPS redundancy.

Banking Data Centers

Multiple Tier III data centers for major banks with dual-path power distribution, N+1 cooling, and integrated DCIM monitoring.

Government Cloud

Large-scale government cloud data center with 5MW IT load, achieving PUE of 1.35 through advanced free cooling design.

Colocation Facilities

Multiple colocation data centers with multi-tenant power metering, flexible cooling zones, and comprehensive environmental monitoring.

Frequently Asked Questions

Common questions about our data center electrical automation services

Plan Your Data Center Project

From greenfield construction to brownfield upgrades, our team delivers end-to-end data center electrical automation with proven Tier III/IV designs and PUE optimization.